HanAra Drivers
Accessing real-time sensor data to connect organizations to needed equipment insight
The value of HanAra’s solutions comes from transforming real-time sensor data into actionable intelligence. In order to provide needed analysis and insight, HanAra solutions must receive real-time equipment data. To simplify the process, HanAra offer a wide range of pre-built interfaces to fit your environment and infrastructure.
| INTERFACE TYPE (CLIENT APPLICATIONS) | PROTOCOL | READ & WRITE |
| OPC DA Client (Real-time, HDA, A&E) | Standard | RW |
| OPC UA Client (Real-time, HDA, A&C) | Standard | RW |
| Modbus Client (Modbus RTU, Modbus TCP, Modbus Over TCP) | Standard | RW |
| ODBC Client | Standard | R |
| MQTT Subscriber | Standard | RW |
| IEC 60870-5-104 Controlling Station | Standard | RW |
| IEC 61850 MMS | Standard | RW |
| DNP3.0 | Standard | RW |
| BACnet | Standard | R |
| Moxa IO Devices | Proprietary | RW |
| GE Mark V (ARCNET based) | Proprietary | RW |
| Siemens Teleperm XP | Proprietary | RW |
| C-NET (IMCS) | Proprietary | RW |
| RTP NetArrays 2200/2300/3000 | Proprietary | RW |
| RONAN SER (SER:Sequence Event Recoder) | Proprietary | RW |
| GSM (GE Standard Messages) 1.0 / 2.0 / 3.0 | Proprietary | RW |
| ABB Procontrol P13 (IPB P42) | Proprietary | RW |
| ABB Procontrol P14 | Proprietary | R |
| iNET Driver for iNET G3 Card for ABB Procontrol P13 | Proprietary | |
| Mitsubishi MIDAS 8000 | Proprietary | RW |
| eDNA Historian | Proprietary | R |
| HF Control System | Proprietary | RW |
To send data to third-party applications, HanAra supports the following interfaces.
| INTERFACE TYPE (CLIENT APPLICATIONS) | PROTOCOL | READ & WRITE |
| OPC DA Server | Standard | RW |
| OPC UA Server | Standard | RW |
| Modbus Server | Standard | R |
| MQTT Publisher | Standard | R |
| DNP3.0 Server | Standard | R |
| ODBC External DB Link | Standard | R |
| HanAra to Cloud | Standard | R |
SOLUTION IMPLEMENTATION

Data Historian Implementation
Implementing a data historian can be a simple process when partnering with a good data historian provider. At HanAra, our historian experts ensure the HanPrism implementation is quick and easy so you make data-informed decisions from the start. Regardless of whether you are replacing a legacy centralized historian or this is your first centralized data historian, our historian experts will guide you during the implementation to ensure a smooth and successful transition.

PdM Implementation
From day 1, our predictive maintenance tool will provide you with needed insight into your equipment health status. We partner with our customers to ensure a simple and straightforward predictive analytics implementation. Let our experts support you on your digital transformation journey.